## Gateway OCPP
##
## Add a OCPP-J gateway
##--------------------------------------------------------------------
## Note: This is an example of how to configure this feature
## you should copy and paste the below data into the emqx.conf for working
gateway.ocpp {
## When publishing or subscribing, prefix all topics with a mountpoint string.
## It's a way that you can use to implement isolation of message routing between different
## gateway protocols
mountpoint = "ocpp/"
## The default Heartbeat time interval
default_heartbeat_interval = "60s"
## The backoff for hearbeat checking times
heartbeat_checking_times_backoff = 1
## Whether to enable message format legality checking.
## EMQX checks the message format of the upstream and dnstream against the
## format defined in json-schema.
## When the check fails, emqx will reply with a corresponding answer message.
##
## Enum with:
## - all: check all messages
## - upstream_only: check upstream messages only
## - dnstream_only: check dnstream messages only
## - disable: don't check any messages
message_format_checking = disable
## Upload stream topic to notify third-party system whats messges/events
## reported by Charge Point
##
## Avaiable placeholders:
## - cid: Charge Point ID
## - clientid: Equal to Charge Point ID
## - action: Message Name in OCPP
upstream {
topic = "cp/${clientid}"
## UpStream topic override mapping by Message Name
topic_override_mapping {
#"BootNotification" = "cp/${clientid}/Notify/BootNotification"
}
reply_topic = "cp/${clientid}/Reply"
error_topic = "cp/${clientid}/Reply"
}
dnstream {
## Download stream topic to receive request/control messages from third-party
## system.
##
## This value is a wildcard topic name that subscribed by every connected Charge
## Point.
topic = "cs/${clientid}"
}
listeners.ws.default {
bind = "0.0.0.0:33033"