This fixes a crash with an error in the log file (see below) that
happened when the MongoDB authorization module queried the database. The
reason is that the collection name that was sent to the mongodb
connection was an atom. This is fixed by making sure it is not an atom.
2023-03-08T17:16:34.215523+01:00 [error] msg: query_mongo_error, mfa:
emqx_authz_mongodb:authorize/4, line: 95, peername: 127.0.0.1:53212,
clientid: client123, collection: mqtt_acl, filter: #{username =>
<<"emqx_u">>}, reason: {resource_error,#{msg => #{error =>
{error,{error_cannot_parse_response,{op_msg_response,#{<<"code">> =>
73,<<"codeName">> => <<"InvalidNamespace">>,<<"errmsg">> => <<"Failed to
parse namespace element">>,<<"ok">> => 0.0}}}},id =>
<<"emqx_authz_mongodb:3">>,name => call_query,request =>
{find,mqtt_acl,#{username => <<"emqx_u">>},#{}},stacktrace =>
[{mc_connection_man,reply,1,[{file,"mc_connection_man.erl"},{line,123}],
...]}, reason => exception}}, resource_id: <<"emqx_authz_mongodb:3">>
Fixes: https://github.com/emqx/emqx/issues/9783
When using async mode with the webhook bridge, queued messages that are
not fully processed when the connection times out could be lost. This
commit fixes this by letting the bridge return a recoverable_error when
this happen. The message send will then be retried in sync mode by the
emqx_resource_buffer_worker.
Fixes: https://emqx.atlassian.net/browse/EMQX-8974
The current schema allows `infinity` for `request_timeout`, so we have
to take that into account. It's not currently possible to set
`batch_time = infinity`, so there's no need to treat that case.
To avoid message loss due to misconfigurations, we adjust `batch_time`
based on `request_timeout`. If `batch_time` > `request_timeout`, all
requests will timeout before being sent if the message rate is low.
Even worse if `pool_size` is high. We cap `batch_time` at
`request_timeout div 2` as a rule of thumb.
flush_time_interval is used to calculate statsd sampling rate:
rate = sample_time_interval / flush_time_interval
This means that flush_time_interval must always be greater than (or equal to)
sample_time_interval, otherwise, the sampling rate will be invalid (> 1).
Relates to EMQX-9055
emqx_config_handler:post_config_update/5 cb is called before an updated config is saved.
Thus, a process being restarted in that callback cannot get the latest config by calling
emqx_conf:get/2, because that update is not saved yet.
Relates to EMQX-9055