Fixes https://emqx.atlassian.net/browse/EMQX-9129
Currently, if an user configures a bridge with query mode sync, then
all calls to the underlying driver/connector ("inner calls") will
always be synchronous, regardless of its support for async calls.
Since buffer workers always support async queries ("outer calls"), we
should decouple those two call modes (inner and outer), and avoid
exposing the inner call configuration to user to avoid complexity.
There are two situations when we want to force synchronous calls to
the underlying connector even if it supports async:
1) When using `simple_sync_query`, since we are bypassing the buffer
workers;
2) When retrying the inflight window, to avoid overwhelming the
driver.
Those tests in the `flaky` test are really flaky and require lots of
CI retries.
Apparently, the flakiness comes from race conditions from restarting
bridges with the same name too fast between test cases. Previously,
all test cases were sharing the same bridge name (the module name).
Also removes the previously added alarm for request timeout.
There are situations where having a short request timeout and a long
health check interval make sense, so we don't want to alarm the user
for those situations. Instead, we automatically attempt to set a
reasonable `resume_interval` value.
This commit makes sure the inflight window setting is present for the
clickhouse bridge. It also changes emqx_resource_schema that previously
removed the inflight window setting from resources with query mode
`always_sync`. We don't need to do that because all bridges that uses
the buffer worker queue will get async call handling even if the bridge
don't support the async callback.
Co-authored-by: Zaiming (Stone) Shi <zmstone@gmail.com>
This commit adds more content to the readme file of the `emqx_rule_engine`
app. The aim of the changes are to make it easier to understand what the
rule engine is and what it does.
Fixes:
https://emqx.atlassian.net/browse/EMQX-9229
Metrics should only be exposed via the /bridges/:id/metrics endpoint,
and not in other operations such as getting the list of all bridges, or
in the response when a bridge has been created. This commit removes all
traces of metrics for the non-dedicated API endpoints.
Fixes https://emqx.atlassian.net/browse/EMQX-9099
The default value for `request_timeout` is 15 seconds, and the default
resume interval is also 15 seconds (the health check timeout, if
`resume_interval` is not explicitly given). This means that, in
practice, if a buffer worker ever gets into the blocked state, then
almost all requests will timeout.
Proposed improvement:
- `request_timeout` should by default be twice as much as
health_check_interval.
- Emit a alarm if `request_timeout` is not greater than
`health_check_interval`.
This was not caught by our tests because we always test bridge types
in isolation. So, if the config only contains ingress-only bridges,
the `on_message_publish` hook is never installed.
In a real system, if there are bridges of mixed types in the config,
the hook might be installed, and `emqx_bridge:get_matched_bridge_id`
would crash when iterating over the ingress bridges.
* Add option to start autocluster. This is useful for scenarios where
a cluster is already running and has some configurations set (via
config handler/cluster rpc) and later another node joins.
* Improve mnesia data directory isolation for nodes. A new dir is set
so that we may avoid intra and inter-suite flakiness due to dirty
tables and schema.
* The janitor is now called synchronously. This ensures the cleanup
is done before the test pid dies.
Kafka Producer and Consumer bridges rely on this prefix for detecting
a dry run and avoid leaking atoms. At some point, this prefix was
changed, effectively disabling the check in Kafka Producer.
1) Make each node have its own isolated data dir to avoid false
negatives.
2) Allow parameterizing the peer module.
3) Fix cluster RPC after a node joins the cluster.
This complements PR https://github.com/emqx/emqx/pull/10124.
The default values for duration_ms() fields needs to be formatted
as a binary string with unit to show up correctly in the dashboard
UI.
For some yet unknown reason the old test version using `open_port`
does not work in OTP 25, but works fine in OTP 24. There are no
messages at all received from The openssl client port program in OTP
25.
Our MongoDB driver creates a new temporary connection, for every active
connection, to just do a single heartbeat test. There is configurable
delay between every heartbeat test. When the user has an EMQX cluster
with a MongoDB bridge (to a MongoDB replica set), there will be a lot of
connections. Furthermore, as MongoDB creates a log entry every time a
new connection is created, the log will be flooded with info about new
connection. One user have reported more than 1MB of log data in a 10
minute period.
This commit tries to fix this by increasing the default delay between
heartbeats. A better fix would be to change the MongoDB driver so that
it does not create a new connection just to do a heartbeat check, but
this is more complicated so we leave this to the future. We might also
swap out the current MongoDB driver to something better.
Fixes:
https://github.com/emqx/emqx/issues/9851
The resource manager may be busy at times, so this change ensures that
getting resource instance state will not block. Currently, no users of
`emqx_resource:get_instance/1` do seem to be relying on state being
"as-actual-as-possible" guarantee it was providing.
Also hexencode non-utf8 binaries. This is essentially an heuristic.
We don't know column types in runtime, and there's no simple way
to find them out. Since we're already doing full binary scan during
escaping it should be cheap to bail out on non-utf8 strings and
hexencode them instead.
Also introduce separate function to highlight that this escaping
is MySQL-specific.
So that mysql client won't attempt to prepare them automatically, thus
trashing the server's prepared statements table and making interaction
overall heavier.
This fixes a crash with an error in the log file (see below) that
happened when the MongoDB authorization module queried the database. The
reason is that the collection name that was sent to the mongodb
connection was an atom. This is fixed by making sure it is not an atom.
2023-03-08T17:16:34.215523+01:00 [error] msg: query_mongo_error, mfa:
emqx_authz_mongodb:authorize/4, line: 95, peername: 127.0.0.1:53212,
clientid: client123, collection: mqtt_acl, filter: #{username =>
<<"emqx_u">>}, reason: {resource_error,#{msg => #{error =>
{error,{error_cannot_parse_response,{op_msg_response,#{<<"code">> =>
73,<<"codeName">> => <<"InvalidNamespace">>,<<"errmsg">> => <<"Failed to
parse namespace element">>,<<"ok">> => 0.0}}}},id =>
<<"emqx_authz_mongodb:3">>,name => call_query,request =>
{find,mqtt_acl,#{username => <<"emqx_u">>},#{}},stacktrace =>
[{mc_connection_man,reply,1,[{file,"mc_connection_man.erl"},{line,123}],
...]}, reason => exception}}, resource_id: <<"emqx_authz_mongodb:3">>
Fixes: https://github.com/emqx/emqx/issues/9783
When using async mode with the webhook bridge, queued messages that are
not fully processed when the connection times out could be lost. This
commit fixes this by letting the bridge return a recoverable_error when
this happen. The message send will then be retried in sync mode by the
emqx_resource_buffer_worker.
Fixes: https://emqx.atlassian.net/browse/EMQX-8974
The current schema allows `infinity` for `request_timeout`, so we have
to take that into account. It's not currently possible to set
`batch_time = infinity`, so there's no need to treat that case.
To avoid message loss due to misconfigurations, we adjust `batch_time`
based on `request_timeout`. If `batch_time` > `request_timeout`, all
requests will timeout before being sent if the message rate is low.
Even worse if `pool_size` is high. We cap `batch_time` at
`request_timeout div 2` as a rule of thumb.
flush_time_interval is used to calculate statsd sampling rate:
rate = sample_time_interval / flush_time_interval
This means that flush_time_interval must always be greater than (or equal to)
sample_time_interval, otherwise, the sampling rate will be invalid (> 1).
Relates to EMQX-9055
emqx_config_handler:post_config_update/5 cb is called before an updated config is saved.
Thus, a process being restarted in that callback cannot get the latest config by calling
emqx_conf:get/2, because that update is not saved yet.
Relates to EMQX-9055
Prior to this change, when EMQX daemon mode failed to start
it's not quite easy for users to understand what went wrong.
All the know is the node did not start in time
and then instructed to boot the node in 'console' mode wishing
for some logs.
However, the node might actuay be running, causing 'console' mode
to fail with a different reason.
With this change, after a filure of daemon mode boot,
we issue a diagnosis.
1. if node can not be found from ps -ef, instruct the user
to find information in erlang.log.N
2. if the node is found running, but not responding to pings
instruct the user to check if the node name is
resolvable and reachable
3. if the node is responding to pings but emqx app is not
running, then it's likely a bug. so the user is advised
to report a github issue.